- Model Name
- Synchronous gravel sealing truck
- نوع الدفع
- L eft or Right hand drive
- Rated payload weight(kg)
- 25000
- وزن المركبة الفارغة
- 12500 كغ
- قاعدة العجلات
- 1800 + 5000 mm
- الأبعاد الكلية
- Approx.11000*2550*3850 mm / 11000mmx2550mmx3850mm
- السرعة القصوى
- 90 كم/س
- طراز المحرك
- YC4Y22-350
- نوع المحرك
- Diesel engine
- No. of cylinders
- Straight-4 cylinders
- سعة المحرك (لتر)
- 10.2
- Max. output (kw)
- 257
- Max. Power speed (rmp)
- 3500
- Max.torque (Nm)
- 2230
- معيار الانبعاثات
- EURO III
- ناقل الحركة
- 12speeds ,12forwards, 2 reverse gear,manual operation
- نظام التوجيه
- Power steering
- Brake
- Air brake
- Air container
- Have
- التجهيز القياسي
- ABS ,Electronic Assistance .Sound,parking sensors
- المحور الأمامي
- 5 tons
- المحور الخلفي
- 10 tons*2
- مواصفات الإطارات
- 11.00R20LT 18PR standard tire, 10tires+ 1 spare tire
- Structure and Materials
- It adopts an elliptical or circular cross-section and a double-layer structure, with high-performance polyurethane foam insulation material filled in the middle. The inner liner is made of corrosion-resistant and high-temperature resistant special steel.
- Capacity range
- 3~20m³
- Key design
- A deflector is installed inside the tank to reduce asphalt sloshing; the bottom is designed with a drainage slope angle for thorough cleaning; and high and low level gauges and observation holes are equipped.
- Independent power unit
- It is usually equipped with a dedicated diesel engine to provide power for the hydraulic system, asphalt pump, and control system of the entire vehicle. It is separated from the chassis driving system to ensure operational stability.
- Fully hydraulic drive
- The main actuating mechanisms (pumps, spray bar lifting and folding, mixing, etc.) all adopt hydraulic transmission, providing strong power and stable control.
- Heating method
- Heat transfer oil heating (mainstream): An independent burner heats the heat transfer oil, which circulates through the heat transfer oil pipes coiled inside the tank/interlayer, indirectly heating the asphalt. Advantages: Uniform heating, less prone to localized aging of asphalt. Direct-fired heating: The flame of the burner directly heats the tank body or the built-in fire tube. The structure is relatively simple, but careful control is required to prevent asphalt aging.
- Smart Temperature Control
- Through the use of multi-point temperature sensors and PID controllers, automatic constant temperature maintenance at a preset temperature is achieved, with temperature variations controlled within ±5ºC.
- Circulatory system
- Outer loop (temperature uniformity): The asphalt pump extracts asphalt from the bottom of the tank (low temperature zone), heats it up using a heater, and sprays it back from the top of the tank, creating convection and eliminating temperature stratification. Internal circulation/stirring (material homogenization): Jetting cycle: The asphalt is sprayed back at high speed through the jetting pipe at the rear of the tank to achieve mixing. It is the most widely used method. Mechanical mixing: For materials prone to segregation such as SBS modified asphalt and rubber asphalt, the use of a hydraulic motor-driven mixing shaft and paddles for forced shear mixing is a key configuration for handling high-end materials.
- Main functions
- High-precision distribution: The error in distribution quantity can be controlled within ±2%. One-click operation: After setting the preset parameters, the spray bar can automatically lift and lower, adjust its width, and activate or deactivate the spray nozzle. Data management: Display and record data such as spraying volume, temperature, vehicle speed, and operation area in real-time, with the ability to store and print, enabling construction quality traceability. Fault self-diagnosis: The system monitors the status of each component and provides early warning of abnormalities.
- Key performance parameters and technical specifications
- Distribution accuracy: ±2% ~ ±3% (industry-leading level). Spraying rate range: Typically 0.3 to 3.0 kg/m² (achieved by changing nozzles). Thermal insulation performance: At an ambient temperature of 20ºC, the static temperature drop is typically ≤10ºC over a 24-hour period. Spraying pressure: The general working pressure is adjustable within the range of 0.2-0.5 MPa. Minimum spraying capacity: Reflects the level of equipment for precision operations (such as fog sealing). Lifting/folding time: The time taken for the spray bar to transition from its transport state to its fully extended operational state impacts preparation efficiency.
- Object
- Asphalt Concrete Pavement
- Mixing Method
- Jet Mixing
- Automatic Grade
- أوتوماتيكي
- Product Capacity
- 40~400t/h
- حجم الخزان
- 3~20m³
- Insulation Layer
- Polyurethane Foam Filling
- Mixing System
- Mechanical Agitation Type, Jet Circulation Type
- Sprinkler Bar
- Hydraulic Folding and Lifting
- Asphalt Pump
- Gear Pump, Rotor Pump
- Control Mode
- Manual, Semi-Automatic, Fully Automatic
- النوع
- Asphalt Distributor
- Moving Type
- Mobile
- حالة المركبة
- جديدة
- Inner Material
- Resistant to Corrosion and High Temperatures
- Heating Method
- Direct-Fired Type, Hot Oil Circulation Type
- Temperature Control Accuracy
- Intelligent Constant Temperature Control
- Nozzle Type
- Fan Shape, Conical Shape